Autodesk 2016 Network license products – New FLEXLM released.

“2016” version of FLEXLM released.

Autodesk announced a policy last year of releasing a version of FLEXLM on each new release of the software.
We recommend that if you intend to run the latest version of the software that you get the latest FLEXLM version otherwise your 2016 software may not pick up it’s license. If you are in the process of installing 2015 product then you will most likely need to upgrade FLEXLM as well.

The procedure for obtaining the latest FLEXLM is shown below.
Please note that there are 2 “flavours” of FLEXLM download that are aimed towards different network protocols (IVP4 and IVP6) -but the one labelled IVP6 supports IVP4/IVP6 mixed environments.

FLEXLM 11.12.1.4- Click here!

Notes for the IVP6 version are here – Click here!

Instructions:

To download the NLM IPv6

Before you can perform any system maintenance on your license server, including updates, you must stop the license server. When you have completed the update, you must restart the license server.
•Download the nlm11.12.1.4_ipv6_win64.exe file to your desktop.

To stop the Network License Server

You should be logged in with Administrator rights when working with the LMTOOLS utility.
1.Right-click the LMTOOLS icon on the desktop and click Run As Administrator.
2.In the LMTOOLS program, click the Start/Stop/Reread tab.
3.On the Start/Stop/Reread tab, click Stop Server, wait 15 seconds, and then proceed.
4.Close lmtools.exe.
5.Locate the existing installed Autodesk Network License Manager files: lmtools.exe, lmutil.exe, lmgrd.exe, and adskflex.exe. Their default location is C:Program FilesAutodesk Network License Manager.
6.Create a back-up copy of the existing Network License Manager files.

To update the Autodesk Network License Manager for IPv6

1.Double-click the nlm11.12.1.4_ipv6_win64.exe file on your desktop. The IPv6 Support files, lmtools.exe, lmutil.exe, lmgrd.exe, and adskflex.exe, are extracted to C:installAutodeskNLMIPv6Support_Win64.
2.Copy the new IPv6 Support files from C:installAutodeskNLMIPv6Support_Win64 to the location where your existing Autodesk Network License Manager is installed.
3.When prompted to replace the existing files, click Yes.

To restart the Network License Server

You should be logged in with Administrator rights when working with the LMTOOLS utility.
1.Right-click the LMTOOLS icon on the desktop and click Run As Administrator.
2.In the LMTOOLS program, click the Start/Stop/Reread tab.
3.On the Start/Stop/Reread tab, click Start Server.
4.Close lmtools.exe.

You should now be able to get users to start their software and they will run as normal.